Bulbs, Fans and Heaters on 220 V: Minimum Fuse Rating

JEE Main 2020 (7 Jan, Shift 2) Q11: 15 bulbs of 45 W, 15 of 100 W, 15 fans of 10 W and 2 heaters of 1 kW on 220 V. Find the minimum fuse rating.

Teaching this question? Turn it into a video

Upload a screenshot and get a narrated whiteboard video in Hinglish, Hindi or English.

Make a video free

Question

A building has 1515 bulbs of 45 W45\ \text{W}, 1515 bulbs of 100 W100\ \text{W}, 1515 small fans of 10 W10\ \text{W} and 22 heaters of 1 kW1\ \text{kW}, all on a 220 V220\ \text{V} supply. What is the minimum fuse rating for the building?

  1. (1)5 A5\ \text{A}
  2. (2)25 A25\ \text{A}
  3. (3)15 A15\ \text{A}
  4. (4)20 A20\ \text{A}✓ Correct

Given

Step-by-step solution

Total power

15(45)+15(100)+15(10)+2(1000)=675+1500+150+2000=4325 W15(45) + 15(100) + 15(10) + 2(1000) = 675 + 1500 + 150 + 2000 = 4325\ \text{W}

Total current

I=PV=4325220≈19.7 AI = \dfrac{P}{V} = \dfrac{4325}{220} \approx 19.7\ \text{A}

The fuse must carry at least this, so the smallest suitable rating is 20 A20\ \text{A}.

Answer: Option (4)

Key idea

Household appliances are in parallel, so their powers add, and the total current is total power divided by the supply voltage.

Common mistake

Rounding 19.7 A19.7\ \text{A} down to 15 A15\ \text{A}: the fuse would blow with everything on.

This question is from JEE Main 2020, 7 January, Shift 2. See all JEE Main previous year questions.

More on this topic: Current Electricity – formulas and solved questions.

Get video solutions for your own questions

Upload any JEE, NEET or CBSE question as a PDF, photo or screenshot and DoubtSolvex AI turns it into a narrated whiteboard video like this one. Try it free.